Military Shelter, HMMWV Mounted
 

Specifications
Drawing



Available On
      

S-710

Performance Specifications:
Designed to meet the shelter performance specification defined in MIL-S-44408

Weight: 680 lbs.

Payload: 3,300 lbs.

Roof Load:
Snow and Ice - 40 lbs./sq. ft.
Personnel and Equipment - 660 lbs. over a sq. ft. area.

Floor Load: 1,000 lbs. over 3 sq. ft. area without permanent deformation

Member Loading: Wall, roof, and floor tensile load 1,000 lbs. followed by 100 inch-pounds torque load 5/16"-18 UNC inserts

Temperature Extremes:
Operating: -65° F to +125° F plus solar load.
Non-operating: -80° F to +160° F

Heat Tranfer: U-factor - 0.40BTU/hr./sq. ft./° F

RFI Shielding: With addition of RFI modification kit, attenuation of 60 dB minimum over 150 kHz to 10 GHz for electric and magnetic fields and plane waves measured IAW MIL-STD-285

Watertightness: Tested to 30 inch fording depth and to simulated rainfall

Lifting Eyes: Four (4) eyes with 3 in. inside clearance. 5,000 lbs. tensile load per corner in any direction

Features:

Roof Access Steps: Two (2) recessed folding steps in sidewall and one roof handhold

Access ladder: Standard ladder with external mounting bracket


Options:

Roof mounted escape hatch

Over-cab equipment pod

Generator tunnel




Wenzlau Engineering | 2950 East Harcourt Street, Rancho Dominguez, California 90221 | Ph. 310.604.3400