Performance Specifications:
Specification MIL-S-55286E
Roof Load:
Snow and Ice - 75 lbs./sq. ft.
Personnel and Equipment - 660 lbs. over a 2 sq. ft. area
Floor Load: 2,500 lbs. over 3 sq. ft. area without permanent deformation
Member Loading: Wall, roof, and floor tensile load 2,000 lbs. followed by 100 inch-pounds torque load (5/16"-18 inserts)
Temperature Extremes:
Operating: -65° F to +125° F plus solar load
Non-operating: -80° F to +160° F
Heat Tranfer: U-factor 0.28 BTU/hr./sq. ft./°F
RFI Shielding: With addition of RFI modification kit, attenuation of 60 dB minimum over 150 kHz to 10 GHz for electric and magnetic fields and plane waves measured IAW MIL-STD-285
Watertightness: Tested to 21 inch fording depth and to simulated rainfall
Lifting Eyes: Four (4) eyes with 3 in. inside clearance. 14,400 lbs. tensile load per corner in any direction
Towing Eyes: Four (4) eyes with 2 in. inside clearance. 14,400 lbs. tensile load per corner in any direction
Features:
Skids: Three (3) full length replaceable shock absorbing type
Roof Access Steps: Three (3) recessed folding steps in sidewall and one roof handhold
Combination lifting/tie down sling to facilitate handling
Options:
RFI modification kit
Mobilizer adapter kit for shelter/transporter interface
|