Military Shelter, Truck Mounted
 

Specifications
Drawing



Available On
      

S-250

Performance Specifications:
Specification MIL-S-55541

Weight:
With EMI kit 762 lbs. min. - 802 lbs. max
Without EMI kit 750 lbs. min. - 790 lbs. max

Payload: 2,530 lbs.

Roof Load:
Snow and Ice 40 lbs./sq. ft.
Ppersonnel and Equipment - 660 lbs. over a 2 sq. ft. area.

Floor Load: 1,000 lbs. over 3 sq. ft. area without permanent deformation

Member Loading: Wall, roof, and floor tensile load 1,000 lbs. followed by 75 inch-pounds torque load 5/16"-18 inserts

Temperature Extremes:
Operating: -65° F to +125° F plus solar load
Non-operating: -80° F to +160° F

Heat Tranfer: U-factor - 0.50BTU/hr./sq. ft./° F. Designed to meet requirements of MIL-S-55541

RFI Shielding: With addition of RFI modification kit, attenuation of 60 dB minimum over 150 kHz to 10 GHz for electric and magnetic fields and plane waves measured IAW MIL-STD-285

Watertightness: Tested to 30 inch fording depth and to simulated rainfall

Lifting Eyes: Four (4) eyes with 3 in. inside clearance. 5,000 lbs. tensile load per corner in any direction

Towing Eyes: Four (4) eyes with 1.50 in. inside clearance. 5,000 lbs. tensile load per corner in any direction


Features:

Skids: Two (2) full length replaceable shock absorbing type

Roof Access Steps: Two (2) recessed folding steps in sidewall and one roof handhold

Lift/Tie Down Slings


Options:

RFI modification kit