Military Shelter, HMMWV Mounted
 



Specifications
Drawing



Available On
      

GSS-1497

Performance Specifications:
Designed to meet the shelter performance specification defined in MIL-S-44408

Weight: 547 lbs.

Payload: 3,300 lbs.

Roof Load:
Snow and Ice - 40 lbs./sq. ft.
Personnel and Equipment - 660 lbs. over a 2 sq. ft. area

Floor Load: 1,000 lbs. over 2 sq. ft. area without permanent deformation

Member Loading: Wall, roof, and floor tensile load 1,000 lbs. followed by 100 inch-pounds torque load 5/16"-18 UNC inserts

Temperature Extremes:
Operating: -65° F to +125° F plus solar load
Non-operating: -80° F to +160° F

Heat Tranfer: U-factor - 0.46 BTU/hr./sq. ft./° F

RFI Shielding: In excess of 60 dB over 150 kHz to 10 GHz for electric and magnetic fields and plane waves measured IAW MIL-STD-285

Watertightness: Tested to 21 inch fording depth and to simulated rainfall

Lifting Eyes: Four (4) eyes with 3 in. inside clearance. 14,400 lbs. tensile load per corner in any direction

Towing Eyes: Four (4) eyes with 1.50 in. inside clearance. 5,000 lbs. tensile load per corner in any direction


Features:

Access Ladder: Standard ladder with external mounting bracket

Roof Access Steps: Two (2) recessed folding steps in sidewall and one roof handhold


Options:

Generator tunnel

Roof mounted escape hatch




Wenzlau Engineering | 2950 East Harcourt Street, Rancho Dominguez, California 90221 | Ph. 310.604.3400